Database
Backup Power Glossary
The spec-sheet terms that actually change what you should buy, explained with worked examples.
- CO Shutoff
- A carbon monoxide sensor on a generator that shuts the engine down if CO builds up around it.
- Dual Fuel Generator
- A generator that can run on either gasoline or propane (LPG), switched with a selector.
- Interlock Kit
- A mechanical plate on the main panel that makes it impossible to have the main breaker and the generator breaker on at the same time.
- Inverter Generator
- A generator that converts its raw output to clean, stable AC electronically, so the engine can throttle down at light load and run quieter.
- L14-30 Outlet
- A 30-amp, 120/240-volt twist-lock outlet found on many portable generators, used to feed a transfer switch or inlet box.
- LiFePO4 (LFP) Battery
- Lithium iron phosphate, the battery chemistry used in most current power stations, rated for thousands of charge cycles.
- MPPT Charge Controller
- Maximum power point tracking: circuitry that pulls the most power a solar panel can give as sun and temperature change.
- NMC Battery
- Lithium nickel manganese cobalt cells, lighter than LiFePO4 but typically rated for fewer charge cycles.
- Parallel Kit
- Cables that join two compatible inverter generators so they act as one with roughly double the output.
- Power Inlet Box
- An outdoor receptacle where you plug a generator cord into the house wiring through a transfer switch or interlock.
- Pure Sine Wave Inverter
- An inverter that produces a smooth AC waveform like utility power, safe for motors, electronics and medical devices.
- Run Time (Generator)
- How long a generator runs on one tank, quoted by makers at a stated load, usually 25% or 50%.
- Running Watts
- The power a generator can deliver continuously, hour after hour. It is the number to size a generator by.
- Solar Generator
- A marketing name for a portable power station sold with solar panels. It stores energy; it does not generate it without the panels.
- Standby Generator
- A permanently installed generator that runs on natural gas or propane and starts automatically when the power goes out.
- Starting Watts (Surge or Peak Watts)
- The brief extra power a generator can supply for a second or two to start motors such as fridge compressors, pumps and AC units.
- Surge Protective Device (SPD)
- A whole-house surge protector mounted at the main panel or meter that diverts voltage spikes to ground.
- THD (Total Harmonic Distortion)
- A measure of how far a generator's AC waveform departs from a clean sine wave. Lower is better for electronics.
- Transfer Switch
- A switch that safely moves selected household circuits from utility power to a generator, so the generator can never feed back into the grid.
- TT-30 (RV 30-Amp)
- The 30-amp, 120-volt RV plug. Not the same as the L14-30 used for home transfer switches.
- UPS Mode (Pass-Through)
- A power station feature that passes wall power to your devices and switches to battery automatically if the power fails.
- Watt-Hours (Wh)
- The amount of energy a battery or power station stores. Divide by your load in watts to estimate runtime.